TS54TDR PRO Test Set
Users Guide
For twisted pair wire, connect the red test lead to a
wire in the cable. Connect the black test lead to
another wire in the cable. If possible, connect to a
wire that is in a different wire pair, or connect to
ground. This increases the strength of the toner
signal emitted from the cable.
3
Make sure that the test set shows 0 VDC.
4
Press M, press D to put the flashing cursor next
to SmartTone, press M, then press M again
to turn on the toner. The display shows
Toner
On
.
If there is voltage on the line, the display shows
SmartTone Volt Detect Lock Out,
and toner will not operate.
5
Use a tone probe to find the place where the tone
is the loudest (Figure 3).
6
To make sure you have found the correct cable,
put a short momentarily across a wire pair in the
cable (Figure 4). If the tone changes, you have
found the correct cable.
To turn off the toner, press
M or Q.
GOL10.EPS
Figure 2. How to Make Connections for the Toner
Punchdown block RJ11 jack
Connect to wires from
different pairs, if possible.