EasyManua.ls Logo

Fluke TS54-A-09-TDR - Software Notice

Fluke TS54-A-09-TDR
36 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
31
Software Notice
Software Notice
This product uses freeRTOS v5.3.0 software. For more
information on freeRTOS, go to http://
www.freertos.org.
The software license statement and files that contain
the binary and source code for freeRTOS v5.3.0 are on
the Fluke Networks website.
Memory Dialing
Memory Capacity
9 speed dial memories plus
one last number redial
memory
Digit Capacity 23 digits per memory
PBX Pause
Duration
User programmable; default
of 4 seconds
Hook Flash
Duration
User programmable; default
of 500 ms
Automatic Shut
Off Duration
User programmable; default
of 2 minutes
Voltage Measurement
Range 4 V dc to 140 V dc
Current Measurement
Range 0 mA to 100 mA
TDR
Range
Accuracy
3,000 feet (914 m)
±2 m ±5 %
SmartTone Toner
Frequencies
Steady tone: 950 Hz
Alternating tones: 950 Hz and
1480 Hz
Battery 9 V alkaline battery
Physical
Dimensions
8.3 in x 3.2 in x 2.6 in
(211 mm x 81 mm x 66 mm)
(without belt clip)
Weight
1.16 lb (0.53 kg)
(without belt clip)
Water Resistance
The tester is rain and moisture
resistant
Environmental
Temperature
Range
Handset speech
and dialing
functions
-22°F to 140 °F (-30°C to 60°C)
LCD function -13°F to 140°F (-25°C to 60°C)
Storage -22°F to 150°F (-30°C to 66°C)
Altitude To 10,000 ft. (3,000 m) max
Relative Humidity
95% to 30°C
75% to 40°C
45% to 50°C
30% to 60°C
Safety
Regulatory
Compliance
Complies with IEC 61010-1:
CAT none, Pollution degree 2
Maximum
Transient Voltage
1500 Vpk
EMC
Complies with EMC EN61326-
1, Portable. Meets FCC CFR
Title 47, Part 15, Subpart B.
Note
Specifications subject to change without notice.

Table of Contents

Related product manuals