4. Country of origin
5. Additional information
6. Phase; type of current; frequency
7. Rated voltage
8. Thermal protection
9. Thermal class
10. Rated shaft power
11. International standard
12. Degree of protection
13. Rated current
14. Rated speed
15. Maximum submergence
16. Direction of rotation: L=left, R=right
17. Duty class
18. Duty factor
19. Product weight
20. Locked rotor code letter
21. Power factor
22. Maximum ambient temperature
23. Read installation manual
24. Notified body. Only for EN-approved Ex-products
Figure 3: The data plate
Approvals
Product approvals for hazardous locations
Pump Approval
• 3153.091
• 3153.095
• 3153.390
• 3153.810
• 3153.830
• 3153.850
European Norm (EN)
• ATEX Directive
• EN 60079-0, EN 60079-1, EN 1127-1
•
I M2 Ex d I
•
II 2 G Ex d IIB T3
EN approval for cable entry:
• Certificate number: INERIS 02ATEX9008 U
•
II 2 G Ex d IIC or I M2 Ex d I
IEC
• IECEx scheme
• IEC 60079–0, IEC 60079–1
• Ex d I
• Ex d IIB T3
Factory Mutural (FM)
• Class I. Div 1. Group C and D
• Dust ignition proof for use in Class II. Div 1. Group E, F and G
• Suitable for use in Class III. Div 1. Hazardous Locations
EN approval plate
This illustration describes the EN approval plate and the information contained in its fields.
Product Description
Flygt 3153 Installation, Operation, and Maintenance Manual 15