Installation
Install the pump
WARNING:
Electrical shock hazard. Check that the cable and cable entry have not been damaged
during transport before installing the pump.
Note that special rules apply to installation in explosive atmospheres.
Make sure that the unit cannot roll or fall over and injure people or damage property.
Do not install CSA-approved products in locations that are classified as hazardous in the
national electric code, ANSI/NFPA 70-2005.
Do not install the starter equipment in an explosive zone unless it is explosion-proof
rated.
WARNING:
A permanent-magnet motor generates voltage when the shaft is rotating. Ensure that the
shaft can not rotate before performing any electrical installation.
NOTICE:
Do not run the pump dry.
Never force piping to make a connection with a pump.
Always remove all debris and waste material from the sump, inlet piping, and
discharge connection, before you install the pump.
These requirements apply:
Use the pump dimensional drawing in order to ensure proper installation.
In S-, T-, and Z-installations the pump must be equipped with cooling jacket
Provide a suitable barrier around the work area, for example, a guard rail.
Check the explosion risk before you weld or use electric hand tools.
Always check the impeller rotation before lowering the pump into the pumped liquid.
If the unit has a permanent magnet motor, ensure that you have read and understood
all safety instructions regarding permanent magnet motors.
Authority regulation
Vent the tank of a sewage machine station in accordance with local plumbing codes.
Fasteners
WARNING:
Only use fasteners of the proper size and material.
Replace all corroded fasteners.
Make sure that all fasteners are properly tightened and that there are no missing
fasteners.
Installation
18 Flygt 3153 Installation, Operation, and Maintenance Manual