Hazardous liquids
The product is designed for use in liquids that can be hazardous to your health. Observe
these rules when you work with the product:
Make sure that all personnel who work with biologically hazardous liquids are
vaccinated against diseases to which they may be exposed.
Observe strict personal cleanliness.
Wash the skin and eyes
Follow these procedures for chemicals or hazardous fluids that have come into contact
with your eyes or your skin:
Condition Action
Chemicals or hazardous
fluids in eyes
1. Hold your eyelids apart forcibly with your fingers.
2. Rinse the eyes with eyewash or running water for at least 15 minutes.
3. Seek medical attention.
Chemicals or hazardous
fluids on skin
1. Remove contaminated clothing.
2. Wash the skin with soap and water for at least 1 minute.
3. Seek medical attention, if necessary.
Ex-approved products
Follow these special handling instructions if you have an Ex-approved unit.
Personnel requirements
These are the personnel requirements for Ex-approved products in potentially explosive
atmospheres:
All work on the product must be carried out by certified electricians and Xylem-
authorized mechanics. Special rules apply to installations in explosive atmospheres.
All users must know about the risks of electric current and the chemical and physical
characteristics of the gas, the vapor, or both present in hazardous areas.
Any maintenance for Ex-approved products must conform to international and national
standards (for example, IEC/EN 60079-17).
Xylem disclaims all responsibility for work done by untrained and unauthorized personnel.
Product and product handling requirements
These are the product and product handling requirements for Ex-approved products in
potentially explosive atmospheres:
Only use the product in accordance with the approved motor data.
You must fully submerge the Ex-approved product during normal operation. Dry
running during service and inspection is only permitted outside the classified area.
Before you start work on the product, make sure that the product and the control panel
are isolated from the power supply and the control circuit, so they cannot be
energized.
Do not open the product while it is energized or in an explosive gas atmosphere.
Make sure that thermal contacts are connected to a protection circuit according to the
approval classification of the product, and that they are in use.
Intrinsically safe circuits are normally required for the automatic level-control system by
the level regulator if mounted in zone 0.
The yield stress of fasteners must be in accordance with the approval drawing and the
product specification.