WS001492A
3. Make sure that the O-ring is removed from the seal housing cover.
WS002008A
4. Measure the trim distance:
a) Place the drive unit in the pump housing.
Make sure that the drive unit is parallel with the pump housing by hand-tightening
the pump housing screws.
WS001475A
b) Check the distance between the seal housing cover and the pump housing with a
feeler gauge.
Check diagonally at four points.