Program Program
Code Function Code Description Entry Code
10 AB06030 Rev. 0.6 5/96
109 Set Time Enter: Five (5) digits. Two (2) digits 109
for hours, Two (2) digits for minutes
and one (1) to indicate military,
time, AM or PM. The last digit will
be "0" = AM, "1" = PM and
"2" = Military (e.g., 01:130) __ __ __ __ __
110 Set Date Enter: Six (6) digits. Two (2) digits for 110
month followed by two (2) digits for
day, followed by (2) digits for
year (e.g., 011288) __ __ __ __ __ __
111 Dynamic Display Enter: Two (2) digits in seconds 111
Time-out of time-out (e.g., 15)
"00" Display will remain till
the "CLEAR" key is pressed __ __
112-139 Unassigned at Present 112-139
140 Protection of Program Enter: "0" for Weights and Measures Mode 140
Codes 180-189 "1" for Program Mode __
141 Local Mode Alarm Enter: One (1) digit from one (1) to 141
Clearing nine (9) indicates the number
of alarms that can be cleared
during a transaction when
in the Run & Ready Mode. (e.g., 3) __
142 Decimal or Comma Enter: "0" Decimal 142
Selection "1" Comma __
143 Alarm Relay Enter: "0" Alarm Relay on Valve Fault 143
"1" Alarm Relay on Any Fault
"2" No Alarm Relay __
144 Run & Ready Mode Enter: "0" English 144
Initialization "1" Not Used
"2" Spanish __
Note: Entry "1" is reserved for future use and is not allowed by the AccuLoad II.
Note: This code applies to SEQ-09 and above firmware.
145 Ready/Run Mode Enter: The number of the alarm that is to 145
Clearable Alarms to be changed (see Appendix for the
Selection alarms, associated numbers and recording
entries.) When the alarm is displayed
enter a "0" if the alarm is allowed to be
cleared in the Ready/Run Mode. Enter a "1"
if the alarm is not allowed to be cleared
in the Ready/Run Mode.
Note: 1. If code 141 is set to "0" the message "No Alarm Clearing" will be displayed and no entries will be allowed.
2. This code applies to SEQ-11 and above firmware.
146-179 Unassigned at Present 146-179
180 Programming Access Enter: Four digit number permits 180
Code entry in to the Program or Weights
and Measures Mode (e.g., 1234) __ __ __ __

Other manuals for FMC Technologies Smith Meter AccuLoad II

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the FMC Technologies Smith Meter AccuLoad II and is the answer not in the manual?

FMC Technologies Smith Meter AccuLoad II Specifications

General IconGeneral
BrandFMC Technologies
ModelSmith Meter AccuLoad II
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals