Program Program
Code Function Code Description Entry Code
AB06030 Rev. 0.6 5/96 19
543 Maximum Pressure Enter: Four (4) digits in tenth 543
Units units for maximum pressure
at 20 mA. (e.g., 4500 = 450.0)
Units dependent on selection
in code 541. "0000" indicates
no pressure transducer installed. __ __ __ . __
544-599 Unassigned at Present 544-599
600
System Read Only Directory
600
601 Injector 1 To be read only None 601
Non-resettable
Totals
602 Injector 2 To be read only None 602
Non-resettable
Totals
603 Injector 3 To be read only None 603
Non-resettable
Totals
604 Injector 4 To be read only None 604
Non-resettable
Totals
605 Injector 5 To be read only None 605
Non-resettable
Totals
606 Injector 6 To be read only None 606
Non-resettable
Totals
607 Injector 7 To be read only None 607
Non-resettable
Totals
608 Local Storage To be read only None 608
Transactions
609-639 Unassigned at Present 609-639
640 Protection of Program Enter: "0" for Weights and Measures Mode 640
Codes 680-689 "1" for Program Mode __
641-699 Unassigned at Present 641-699
700
System Communication Directory
700
701 EIA-232 Enter: "0" No Communications 701
Communication "1" for EIA Type Terminal
Type "2" for EIA Type Minicomputer
"3" Gate City Additive System __
Note:
Option "3" applies to SEQ-13 and above firmware.
702 EIA-232 Enter: "0" for Poll Only 702
Communication "1" for Poll and Authorize
Control "2" for Remote Control
"3" for Auto Out
"4" for Shared Auto Out
"5" Smart Additives __
Note:
Option "5" applies to SEQ-13 and above firmware.