EasyManuals Logo
Home>FMC Technologies>Measuring Instruments>Smith Meter AccuLoad II

FMC Technologies Smith Meter AccuLoad II Programming Workbook

FMC Technologies Smith Meter AccuLoad II
63 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #37 background imageLoading...
Page #37 background image
Program
Code Function Code Description Prod 1 Prod 2 Prod 3 Prod 4
AB06030 Rev. 0.6 5/96 35
350 Meter Factor Enter: Four (4) digits representing
Reference the temperature that the percent
Temperature meter factor variation was determined,
Three (3) whole units and one
(1) decimal in degrees (i.e., 120.1) _____._ _____._ _____._ _____._
351-389 Unassigned at Present
390 Master Meter Factor Enter: Five (5) digits as one (1)
whole number followed by
four (4) decimals (e.g., 1.0040)
Restricts meter factors 1
through 4, Program codes 353, 355
357, and 359 to +/- 2% of this
entry. Enter 0.0000 to disable
this feature. _._____ _._____ _._____ _._____
391 Linearized Factor Enter: Three (3) digits in a percentage,
Deviation one (1) whole number followed by two
(2) decimals (e.g., 3.40). Restricts
deviation between adjacent meter
factors. Enter 0.00 to disable
this feature. _.___ _.___ _.___ _.___
392 Meter Factor Variation Enter: "0" No Meter Factor Variation
"1" Yes Meter Factor Variation __ __ __ __
393-399 Unassigned at Present
400
Temperature & Density Directory
401-439 Unassigned at Present
440 Protection of Program Enter: "0" for Weights and Measures Mode
Codes 480-489 "1" for Program Mode __ __ __ __
441 API Table & Product Enter: "00" No API Table "12" API Table 24A
"01" API Table 5A "13" API Table 24B
"02" API Table 5B "14" API Table 24D
"03" API Table 5D "15" API Table 53A
"04" API Table 6A "16" API Table 53B
"05" API Table 6B "17" API Table 53D
"06" API Table 6C "18" API Table 54
"07" API Table 6D "19" API Table 54A
"08" API Table 23A "20" API Table 54B
"09" API Table 23B "21" API Table 54C
"10" API Table 23D "22" API Table 54D
"11" API Table 24 ___ ___ ___ ___
442 Reference Density Enter: Five (5) digit density
with floating decimal.
(e.g., 0999.9 to 0.9999
depending on selection in
code 441). _____________________ _______

Other manuals for FMC Technologies Smith Meter AccuLoad II

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the FMC Technologies Smith Meter AccuLoad II and is the answer not in the manual?

FMC Technologies Smith Meter AccuLoad II Specifications

General IconGeneral
BrandFMC Technologies
ModelSmith Meter AccuLoad II
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals