Program Program
Code Function Code Description Entry Code
AB06030 Rev. 0.6 5/96 17
358 Recipes Per Enter: "0" Single Recipe/Transaction 358
Transaction "1" Multiple Recipes/Transaction __
359 Auto Proving Select Enter: "0" Auto Proving Disabled 359
"1" Auto Proving Enabled
"2" Auto Proving Always __
Note: This code applies to SEQ-12 and above firmware.
360-389 Unassigned at Present 360-389
390 Input Pulse Type Enter: "0" Active Pulse Input 390
"1" Contact Type Input __
391 Input Pulse Doubler Enter: "0" Pulses Times One 391
"1" Pulses Times Two __
392 Transmitter Type Enter: "0" Single Channel 392
"1" Single and Inverted
"2" Dual Channel
"3" Dual and Inverted __
393-399 Unassigned at Present 393-399
400
System Temperature & Density Directory
400
401-439 Unassigned at Present 401-439
440 Protection of Program Enter: "0" for Weights and Measures Mode 440
Codes 480-489 "1" for Program Mode __
441 Temperature Units Enter: "0" No Temperature Probe 441
"1" Fahrenheit
"2" Celsius __
442 Reference Enter: Four (4) digit reference 442
Temperature temperature in tenth degrees
(e.g., 060.0) __ __ __ . __
443 Temperature Offset Enter: Three (3) digits. First digit 443
must be "0" or "1" (0 = positive,
1 = negative). Second and third
digits represent the offset temperature
in tenth degrees (e.g., 10.5 entered
will display as -0.5 degrees offset) __ __ . __
444 Density or Enter: "0" Density Input 444
Temperature Input "1" Temperature Input __
Note: If Temperature is selected AccuLoad II will ignore the RTD channel. To accept readings from the RTD channel this entry must be selected
for density input.
445 Density Units Enter: "0" No Densitometer Installed 445
"1" Lbs/Ft
3
.
"2" Kgs/M
3
.__