EasyManuals Logo

FMC Technologies Smith Meter AccuLoad II Programming Workbook

FMC Technologies Smith Meter AccuLoad II
63 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #33 background imageLoading...
Page #33 background image
Program Program
Code Function Code Description Entry Code
AB06030 Rev. 0.6 5/96 31
864 Additive Feedback Enter: "0" Additive Feedback Alarm with 864
Alarm Shut-down.
"1" Additive Feedback Alarm Message
at the End of the Batch with No
Shut-down. __
Note: This code applies to SEQ-05 and above firmware.
865 Additive Totals Enter: "0" Gallons 865
Units "1" Liters __
Note: 1. This code applies to SEQ-13 and above firmware.
2. If a Smart Additive Subsystem is selected, this code will be used rather than 855.
866-879 Unassigned at Present 866-879
880 Additive Injector Enter: Three (3) digits in whole units 880
Pulser No. 1 defining the amount of mainstream
product for each injection cycle.
(e.g., 040) __ __ __
881 Additive Injector Enter: Three (3) digits in whole units 881
Pulser No. 2 defining the amount of mainstream
product for each injection cycle.
(e.g., 040) __ __ __
882 Additive Injector Enter: Three (3) digits in whole units 882
Pulser No. 3 defining the amount of mainstream
product for each injection cycle.
(e.g., 040) __ __ __
883 Additive Injector Enter: Three (3) digits in whole units 883
Pulser No. 4 defining the amount of mainstream
product for each injection cycle.
(e.g., 040) __ __ __
884 Additive Injector Enter: Three (3) digits in whole units 884
Pulser No. 5 defining the amount of mainstream
product for each injection cycle.
(e.g., 040) __ __ __
885 Additive Injector Enter: Three (3) digits in whole units 885
Pulser No. 6 defining the amount of mainstream
product for each injection cycle.
(e.g., 040) __ __ __
886 Additive Injector Enter: Three (3) digits in whole units 886
Pulser No. 7 defining the amount of mainstream
product for each injection cycle.
(e.g., 040) __ __ __
887-899 Unassigned at Present 887-899
900
System Diagnostic Directory
900
901 Diagnostic Display Test None 901
902 Diagnostic Keypad Test None 902
903 Diagnostic RTD Test None 903
904 Diagnostic 4 - 20 mA Channel 1 None 904
905 Diagnostic 4 - 20 mA Channel 2 None 905
906 Diagnostic Internal Temperature None 906
907 Diagnostic Power Supply Test None 907

Other manuals for FMC Technologies Smith Meter AccuLoad II

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the FMC Technologies Smith Meter AccuLoad II and is the answer not in the manual?

FMC Technologies Smith Meter AccuLoad II Specifications

General IconGeneral
BrandFMC Technologies
ModelSmith Meter AccuLoad II
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals