Program Program
Code Function Code Description Entry Code
30 AB06030 Rev. 0.6 5/96
853 Additive Injector #7 Enter: "0" No Injector 3 Feedback 853
Feedback "1" Injector 3 Feedback/Control
"2" Injector 3 Feedback Only __
854 Additive Injector #7 Enter: Six (6) digits defining 854
Volume the volume of additive to be
injected for each Additive Injector
cycle (e.g., 001.000) __ __ __ . __ __ __
Note: Only one decimal place for Smart Additive Injectors.
855 Injector Units Enter: Three (3) character message 855
identifying the injector units
(e.g., Ozs) __ __ __
Note: This code not used with Smart Additive Subsystems.
856 Additive Injector Enter: Two (2) digits defining 856
Feedback Errors the number of errors before alarming __ __
Note: This code not used with Smart Additive Subsystems.
857 Injector #1 Feedback Enter: Three (3) digits in seconds 857
Delay allowed between feedbacks before
an alarm. __ __ __
Note: This code not used with Smart Additive Subsystems.
858 Injector #2 Feedback Enter: Three (3) digits in seconds 858
Delay allowed between feedbacks before
an alarm. __ __ __
Note: This code not used with Smart Additive Subsystems.
859 Injector #3 Feedback Enter: Three (3) digits in seconds 859
Delay allowed between feedbacks before
an alarm. __ __ __
Note: This code not used with Smart Additive Subsystems.
860 Injector #4 Feedback Enter: Three (3) digits in seconds 860
Delay allowed between feedbacks before
an alarm. __ __ __
Note: This code not used with Smart Additive Subsystems.
861 Injector #5 Feedback Enter: Three (3) digits in seconds 861
Delay allowed between feedbacks before
an alarm. __ __ __
Note: This code not used with Smart Additive Subsystems.
862 Injector #6 Feedback Enter: Three (3) digits in seconds 862
Delay allowed between feedbacks before
an alarm. __ __ __
Note: This code not used with Smart Additive Subsystems.
863 Injector #7 Feedback Enter: Three (3) digits in seconds 863
Delay allowed between feedbacks before
an alarm. __ __ __
Note: This code not used with Smart Additive Subsystems.

Other manuals for FMC Technologies Smith Meter AccuLoad II

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the FMC Technologies Smith Meter AccuLoad II and is the answer not in the manual?

FMC Technologies Smith Meter AccuLoad II Specifications

General IconGeneral
BrandFMC Technologies
ModelSmith Meter AccuLoad II
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals