Program
Code Function Code Description Prod 1 Prod 2 Prod 3 Prod 4
34 AB06030 Rev. 0.6 5/96
212 Block Valve Delay Enter: Two (2) digits in
to Open seconds of delay time
(e.g., 05) ___ ___ ___ ___
213-239 Unassigned at Present
240 Protection of Program Enter: "0" for Weights and Measures Mode
Codes 280-289 "1" for Program Mode __ __ __ __
241 Block Valve Security Enter: "0" for No Security
"1" for Security __ __ __ __
242-299 Unassigned at Present
300
Volume Accuracy Directory
301 Minimum Batch Enter: Five (5) digits in
Volume whole units (e.g., up
to 99,999 units) ____________________________
302-339 Unassigned at Present
340 Protection of Program Enter: "0" for Weights and Measures Mode
Codes 380-389 "1" for Program Mode __ __ __ __
341 Flow Rate for Enter: Four (4) digits in whole units
Meter Factor #1 per minute (e.g., 0600) _____ _____ _____ _____
342 Meter Factor #1 Enter: Five (5) digits as one (1) whole
number followed by four (4)
decimals (e.g., 1.0033) _._____ _._____ _._____ _._____
343 Flow Rate for Enter: Four (4) digits in whole units
Meter Factor #2 per minute (e.g., 0400) _____ _____ _____ ______
Note:
If the flow rate is set at zero the AccuLoad II will ignore codes 344 through 348.
344 Meter Factor #2 Enter: Five (5) digits as one (1) whole
number followed by four (4)
decimals (e.g., 1.0040) _._____ _._____ _._____ _._____
345 Flow Rate for Enter: Four (4) digits in whole units
Meter Factor #3 per minute (e.g., 0150) _____ _____ _____ _____
Note:
If the flow rate is set at zero the AccuLoad II will ignore codes 346 through 348.
346 Meter Factor #3 Enter: Five (5) digits as one (1) whole
number followed by four (4)
decimals (e.g., 1.0048) _._____ _._____ _._____ _._____
347 Flow Rate for Enter: Four (4) digits in whole units
Meter Factor #4 per minute (e.g., 0080) _____ _____ _____ _____
Note:
If the flow rate is set at zero the AccuLoad II will ignore code 348.
348 Meter Factor #4 Enter: Five (5) digits as one (1) whole
number followed by four (4)
decimals (e.g., 1.0058) _._____ _._____ _._____ _._____
349 Meter Factor % Enter: Five (5) digits representing
Change/Deg. the meter factor percent change
per degree of unit temperature in
percentage, (e.g., 0.0012) _._____ _._____ _._____ _._____

Other manuals for FMC Technologies Smith Meter AccuLoad II

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the FMC Technologies Smith Meter AccuLoad II and is the answer not in the manual?

FMC Technologies Smith Meter AccuLoad II Specifications

General IconGeneral
BrandFMC Technologies
ModelSmith Meter AccuLoad II
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals