Program Program
Code Function Code Description Entry Code
AB06030 Rev. 0.6 5/96 27
767-779 Unassigned at Present 767-779
780 Number of Prompts Enter: One (1) digit between 0 780
and 5 representing the number of
prompts used in the Standby Mode (e.g., 4)
"0" Disables prompts in the Standby Mode __
781 Print Transaction Enter: Three (3) digit Transaction 781
Number to print the transaction
data desired. (e.g., 010 will
print the tenth transaction back
from the current transaction.) __ __ __
782 Prompts Printed Enter: "0" Standby Blank 782
"1" Standby Print
"2" Always Print __
783-799 Unassigned at Present 783-799
800
System Input/Output Directory
800
801 Additive Injector Stop Enter: "0" Additive stop at end 801
of batch (Injector Option 1)
"1" Additive stop at First
trip point with no
recalculation (Injector Option 2)
"2" Additive stop at First
trip point with recalculation
(Injector Option 3)
"3" Additive stop at Additive Injector
stop volume with no recalculation
of additive (Injector Option 4)
"4" Additive Stop at Additive Injector
stop volume with recalculation
of additive (Injector Option 5) __
Note:
1. Selection 2 (Injector Option 3) applies to SEQ-02 and above firmware.
2. Selections 3 and 4 (Injector Options 4 and 5) apply to SEQ-13 and above firmware.
802 Additive Injector Enter: "0" for Raw Output 802
Output "1" for Gross Output
"2" for Gst Output
"3" for Net Output __
803 Manual/Auto Enter: "0" for Auto Injectors 803
Additive Injector "1" for Manual Injectors
Selection when in the Standby Mode.
"2" for Manual Injectors
per transaction.
"3" for Manual Injectors
per batch. __
804 Restart After Enter: "0" Manual Valve Start 804
Valve Power "1" Auto Valve Start __
Restored
805 Valve Power Sense Enter: Up to twenty (20) characters 805
Permissive Message for prompt message
(e.g., Permissive Not Met) ____________

Other manuals for FMC Technologies Smith Meter AccuLoad II

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the FMC Technologies Smith Meter AccuLoad II and is the answer not in the manual?

FMC Technologies Smith Meter AccuLoad II Specifications

General IconGeneral
BrandFMC Technologies
ModelSmith Meter AccuLoad II
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals