Program
Code Function Code Description Prod 1 Prod 2 Prod 3 Prod 4
36 AB06030 Rev. 0.6 5/96
443 Low Temperature Enter: Four (4) digits. The
Alarm first digit indicates polarity.
First digit "0" = Positive
First digit "1" = Negative
The last three (3) digits
indicate temperature in whole
degrees. (e.g., 0020 = + 020)
Temperature units are dependent
on entry made in code 441.
An entry of -999 will disable
this feature. _____ _____ _____ _____
444 High Temperature Enter: Four (4) digits. The
Alarm first digit indicates polarity.
First digit "0" = Positive
First digit "1" = Negative
The last three (3) digits
indicate temperature in whole
degrees. (e.g., 0250 = + 250)
Temperature units are dependent
on entry made in code 441.
An entry of 0999 (+999) will
disable this feature. _____ _____ _____ _____
445 Maintenance Temperature Enter: Five (5) digits. The
first digit indicates polarity.
First digit "0" = Positive
First digit "1" = Negative
The last four (4) digits
indicate temperature in tenths
of degrees. An entry of -999.9
will disable this feature.
(e.g., 0085.0 = + 85.0) ______._______._______._______._
Note: Any entry other than -999.9 will override the RTD or 4-20 mA Temperature Input and will be used in all calculations using the temperature
factor.
446 Low Density Alarm Enter: Four (4) digits. The
range is from 0000 to 9999.
Density units are dependent
on entry made in code 445
of the Systems Directory.
An entry of 0000 will disable
this feature. _____ _____ _____ _____
447 High Density Alarm Enter: Four (4) digits. The
range is from 0000 to 9999.
Density units are dependent
on entry made in code 445
of the Systems Directory.
An entry of 0000 will disable
this feature. _____ _____ _____ _____
448-499 Unassigned at Present

Other manuals for FMC Technologies Smith Meter AccuLoad II

Questions and Answers: