Program Program
Code Function Code Description Entry Code
20 AB06030 Rev. 0.6 5/96
703 EIA-232 Baud Rate Enter: "0" for 110 Baud 703
"1" for 150 Baud
"2" for 300 Baud
"3" for 600 Baud
"4" for 1200 Baud
"5" for 2400 Baud
"6" for 3600 Baud
"7" for 4800 Baud
"8" for 7200 Baud
"9" for 9600 Baud __
704 EIA-232 Data Format Enter: "0" EIA-232 7 Bits Even 704
"1" EIA-232 7 Bits Odd
"2" EIA-232 7 Bits None
"3" EIA-232 8 Bits Even
"4" EIA-232 8 Bits Odd
"5" EIA-232 8 Bits None __
705 EIA-485 Enter: "0" No Communications 705
Communication "1" EIA Type Terminal
Type "2" EIA Type Minicomputer
"3" Gate City Additive System __
Note: Option "3" applies to SEQ-13 and above firmware.
706 EIA-485 Enter: "0" for Polling only 706
Communication "1" for Poll and Authorize
Control "2" for Remote Control
"3" for Auto Out
"4" for Shared Auto Out
"5" Smart Additives __
Note: Option "5" applies to SEQ-13 and above firmware.
707 EIA-485 Baud Rate Enter: "0" for 110 Baud 707
"1" for 150 Baud
"2" for 300 Baud
"3" for 600 Baud
"4" for 1200 Baud
"5" for 2400 Baud
"6" for 3600 Baud
"7" for 4800 Baud
"8" for 7200 Baud
"9" for 9600 Baud __
708 EIA-485 Data Format Enter: "0" EIA-485 7 Bits Even 708
"1" EIA-485 7 Bits Odd
"2" EIA-485 7 Bits None
"3" EIA-485 8 Bits Even
"4" EIA-485 8 Bits Odd
"5" EIA-485 8 Bits None __
709 Communication Enter: Two (2) digit number to 709
Address identify the unit location
for communications, range
01 to 99 (e.g., 25) __ __