Program Program
Code Function Code Description Entry Code
12 AB06030 Rev. 0.6 5/96
204 Zero Flow Timer Enter: Two (2) digits in seconds (e.g., 15) 204
"00" disables this option __ __
205 Overrun Alarm Limit Enter: Two (2) digits in whole 205
units (e.g., 15)
"00" disables the alarm __ __
206 Start Delay After Stop Enter: Three (3) digits in whole 206
seconds of delay time
(e.g., 020) __ __ __
207 Pump Relay Time Enter: Two (2) digits in 207
Delay seconds of delay time
(e.g., 09) __ __
208 Valve Delay To Open Enter: Two (2) digits in seconds 208
of delay time. (e.g., 07)
"00" disables option __ __
209 PT/VF Time Delay Enter: Two (2) digits in seconds 209
of time delay (e.g., 15)
Entry must not be "00" __ __
210 Flow Control Valve Enter: "0" for a Digital Valve 210
"1" for a Two-stage Valve __
211 Zero Flow Alarm Enter: "0" Zero Flow Alarm Disabled 211
"1" Zero Flow Alarm Enabled __
Note: This code applies to SEQ-11 and above firmware.
212-239 Unassigned at Present 212-239
240 Protection of Program Enter: "0" for Weights and Measures Mode 240
Codes 280-289 "1" for Program Mode __
241 Flow Control Valve Enter: "0" for No Security 241
Security "1" for Security __
242-279 Unassigned at Present 242-279
280 Clean Line Product Enter: "1" for Product 1 280
"2" for Product 2
"3" for Product 3
"4" for Product 4 __
281 Clean Line Volume Enter: Three (3) digits in whole 281
units of product to be left
in the line at the end of
the batch. (e.g., 050) __ __ __
Note: The Clean Line Volume is always subtracted from 1st product in the recipe
282 Clean Line Alarm Enter: Two (2) digits in volume 282
Limit of under delivery of the
clean line volume allowed.
(e.g., 10) __ __