Program Program
Code Function Code Description Entry Code
AB06030 Rev. 0.6 5/96 15
341 Dual Pulse Error Enter: Three (3) digits indicating 341
Count the number of error counts
from the Dual Pulse Comparator
prior to alarming. (e.g., 050) __ __ __
Note: "000" disables the error counting.
342 Dual Pulse Error Enter: "0" No DPC Error Reset 342
Reset "1" Reset at the End of Transaction Only
"2" Reset Upon Power-up Only
"3" Reset Upon Power-up and
at the End of Each Transaction __
343 Dual Pulse Flow Enter: Three (3) digits defining 343
Rate Cutoff the flow rate that the
Dual Pulse errors will begin
to be counted. __ __ __
344 Display Units Enter: Three (3) character message 344
identifying the display units
(e.g., GAL) __ __ __
345 Corrected Display Enter: "0" No Correction 345
"1" Correct Delivery Display
"2" Corrected Preset Display
"3" Corrected Delivery & Preset __
346 Pulse #1 Enter: "0" Raw Pulse Out 1 346
Output "1" Gross Pulse Out 1
"2" Gst Pulse Out 1
"3" Net Pulse Out 1
"4" Mass Pulse Out 1 __
347 Pulse #1 Output Enter: Four (4) digits defining 347
Resolution the pulse output resolution
(units/pulse) in tenth units,
"0000" Disables this feature
(e.g., 010.0) __ __ __ . __
Note: Input pulses must be 2.5 times greater than the output pulses (e.g., 100 output pulses/unit volume requires at least 250 input
pulses/unit volume).
348 Pulse #2 Enter: "0" Raw Pulse Out 2 348
Output "1" Gross Pulse Out 2
"2" Gst Pulse Out 2
"3" Net Pulse Out 2
"4" Mass Pulse Out 2 __