Program Program
Code Function Code Description Entry Code
22 AB06030 Rev. 0.6 5/96
741 Communication Link Enter: "0" for No Program Code Values 741
Programming "1" for Program Values Only
"2" for Program and Weights and
Measures Values
"3" for Alarm Reset Only __
742 Communications Enter: Three (3) digits in seconds 742
Time-out that communication polling may
be absent (e.g., 060)
"000" disables the Communications
Alarm Mode __ __ __
743 Communications Enter: "0" Standby Mode 743
Alarm Mode "1" Communications Alarm Mode
"2" Standby and Communications
Alarm Mode __
744 Prompt Time-out Enter: Three (3) digits in seconds 744
of time-out allowed with each
prompt (e.g., 015) __ __ __
Note: Minimum time-out is 10 seconds.
745 Prompt Data Entry #1 Enter: Two (2) digits representing 745
the prompt data response.
First digit "0" = Displayed
First digit "1" = Hidden Display
Second digit "0 - 9" = Digits for
prompt entry (e.g., 04) __ __
746 Prompt Data Entry #2 Enter: Two (2) digits representing 746
the prompt data response.
First digit "0" = Displayed
First digit "1" = Hidden Display
Second digit "0 - 9" = Digits for
prompt entry (e.g., 15) __ __
747 Prompt Data Entry #3 Enter: Two (2) digits representing 747
the prompt data response.
First digit "0" = Displayed
First digit "1" = Hidden Display
Second digit "0 - 9" = Digits for
prompt entry (e.g., 15) __ __
748 Prompt Data Entry #4 Enter: Two (2) digits representing 748
the prompt data response.
First digit "0" = Displayed
First digit "1" = Hidden Display
Second digit "0 - 9" = Digits for
prompt entry (e.g., 16) __ __