Code Function Code Description Prod 1 Prod 2 Prod 3 Prod 4
38 AB06030 Rev. 0.6 5/96
543 Low Vapor (P1) Enter: Four (4) digits indicating
Pressure the low vapor pressure in PSIA, Bars
or kg/cm
2
in tenths of pressure
units, (e.g., 006.0).
Pressure units are dependent
on entry made in code 541
of Systems Directory. ____._ ____._ ____._ ____._
544 Low Product Vapor Enter: Four (4) digits in Degrees C
Pressure (P1) or Degrees F that corresponds
Temperature to the low vapor pressure in
code 543.
First digit "0" = Plus Degrees
First digit "1" = Minus Degrees
(e.g., 1150=-150). Temperature units are
dependent on entry made in code 441
of the Systems Directory. _____ _____ _____ _____
545 Middle Vapor Enter: Four (4) digits indicating
Pressure (P2) the middle vapor pressure in PSIA, Bars
or kg/cm
2
in tenths of pressure
units, (e.g., 020.0).
Pressure units are dependent
on entry made in code 541
of the Systems Directory. ____._ ____._ ____._ ____._
Note: This entry must exceed the entry made is 543 or it will be ignored.
546 Middle Product Vapor Enter: Four (4) digits in Degrees
Pressure (P2) C or Degrees F that corresponds
Temperature to the middle vapor pressure
in code 545.
First digit "0" = Plus Degrees
First digit "1" = Minus Degrees
(e.g., 0030 = +030). Temperature units are
dependent on entry made in code 441
of the Systems Directory. _____ _____ _____ _____
547 High Vapor Enter: Four (4) digits indicating
Pressure (P3) the high vapor pressure in PSIA, Bars
or kg/cm
2
in tenths of pressure
units, (e.g., 100.0).
Pressure units are dependent
on entry made in code 541
of the Systems Directory. ____._ ____._ ____._ ____._
Note: This entry must not exceed the entry made in 545 or it will be ignored.
548 High Product Vapor Enter: Four (4) digits in Degrees
Pressure (P3) C or Degrees F that corresponds
Temperature to the high vapor pressure
in code 546.
First digit "0" = Plus Degrees
First digit "1" = Minus Degrees
(e.g., 0600 = +060). Temperature units are
dependent on entry made in code 441
of the Systems Directory. _____ _____ _____ _____

Other manuals for FMC Technologies Smith Meter AccuLoad II

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the FMC Technologies Smith Meter AccuLoad II and is the answer not in the manual?

FMC Technologies Smith Meter AccuLoad II Specifications

General IconGeneral
BrandFMC Technologies
ModelSmith Meter AccuLoad II
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals