EasyManua.ls Logo

Follett REF20-PH - Automatic Defrosting

Follett REF20-PH
36 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
01134592 – REF20/25 LB, PH, BB 17
Annual cleaning
Fig. 31
Removal of dust and other particulates from air intake areas and the
condenser is important for proper operation. Environments with large
amounts of dust may require more frequent cleaning.
1. Disconnect power to unit by turning power switch off (located on upper
front facade panel) and removing power cord from receptacle.
2. The condenser can be accessed from top for cleaning. The side
panel in front of condenser may be completely removed for easier
cleaning by disconnecting facade and removing upper side panel.
See Face Removal for facade removal instructions.
3. Inspect drain pan for any debris or obstruction in condensate pan
(Fig.31.1).
4. Use a vacuum cleaner with brush attachment to clean condenser,
compressor and related parts.
5. Reinstall upper side panel and facade if removed.
Defrosting
REF20/25 series upright refrigerators do not require manual defrosting. The evaporator defrosts automatically
when the refrigeration unit is in the OFF cycle. The evaporator fan will run continuously.
1