Refrigeration System
The Performance Plus refrigeration system is designed to give many years of trouble-free service. Except for routine
cleaning of the air-cooled condenser and related parts, the refrigeration system requires no service or maintenance.
The system uses a capillary tube and is critically charged. The connection of refrigeration service hoses to the
ttings will almost invariably result in a signicant change in the system charge. This change can adversely affect the
performance of your refrigerator. Therefore, Follett recommends that if hoses are ever connected to the refrigeration
system for service, the refrigerant should be recovered, the system evacuated, and recharged by weighing in the
correct refrigerant charge.
Specications
REFVAC4P 31.38" (79.7 cm) H x 23.75"
(60.3cm) W x 27"(68.5 cm) D
Fits below 34" (86.4 cm) high ADA-
compatible counter
3.9 cu ft capacity (Usable
space: 2.65 cu ft (0.08 m
3
)
REFVAC5P 34.00" height (86.4 cm) H x 23.75"
(60.3 cm) W x 27"(68.5 cm) D
Fits below standard 36" (91.4 cm)
high counter
4.5 cu ft capacity (Usable
space: 3.04 cu ft (0.09 m
3
))
Electrical Specications
§ 115 V, 60 Hz, 1 phase
§ Full load: 4.1A
§ Minimum circuit ampacity: 15A
§ Connect to dedicated circuit, fuse or breaker
§ Maximum size of branch circuit overcurrent device: 15A breaker
Refrigeration Specications
Refrigerant Charge Size (oz)
Maximum Design Pressures (psi)
High Side Low Side
R134A 7.5 190 110
Installation Specications
Ambient temperature must not exceed 39 C (100 F).
The front louvered panel must be kept free of any cabinet trim or obstructions to ensure proper ventilation of the
refrigeration system.
CAUTION!
§ Equipment must be wired according to local and national electrical codes.
§ Always disconnect power before servicing refrigerator.
REFVAC4P, REFVAC5P Undercounter Refrigerators 3