5100ex Calibration Manual
Firmware Version
3.8

Table of Contents

Questions and Answers

  • C
    Colleen SimpsonAug 11, 2025
    What to do if Force 5100ex shows 'Value above max'?
    • S
      Shelby WilliamsAug 11, 2025
      If the Force Controller displays 'Value above max,' it means the device recorded more than 200,000 pulses, potentially due to excess noise, connection to a digital communication circuit, or driving too far. To resolve this: * Check the wiring and connections of the speedometer cable. * Ensure the Speedometer Type is correctly configured. * Reduce the Low Trip Point. * Increase the High Trip Point.
  • G
    Gary WestAug 26, 2025
    Why does my Force Controller say 'Value below min'?
    • H
      huntdavidAug 27, 2025
      If your Force Controller displays 'Value below min,' it indicates that the device recorded less than 5000 pulses. This can be caused by a disconnected or intermittent speedometer signal, or not driving far enough. To fix this issue: * Check the wiring and connections of the speedometer cable. * Ensure the Speedometer Type is set correctly. * Increase the Low Trip Point. * Decrease the High Trip Point.