5. Installation
Consumables
Table 14: Consumables
Name Type Quantity
Adhesive UHU PLUS BLACK (UH45685) As required
Adhesive ergo.® 6305 or Sikaflex-521UV As required
Cleaning agent Isopropanol As required
Attaching the Sensor
Conditions:
■
Ambient temperature +10 ... + 40 °C.
■
Installation position is prepared. See Preparing the Installation Position, page 21.
Attaching the sensor:
1. Optional: Preheat the installation position to accelerate the curing process. Ensure
that the maximum allowable temperature of the substrate is not exceeded.
2. Ensure that the structure at the installation position is at rest strain.
3. Attach the Mixing Tip short / 77mm to the mixing gun.
4. Insert the UHU PLUS BLACK cartridge into the mixing gun.
5. Press UHU PLUS BLACK with the mixing gun into a suitable container until the
Mixing Tip short / 77mm has been flushed once.
6. Remove the protective film from the bottom of the fos4Strain expert.
28 / 42 4-10_1.3.x_4.0_fos4Strain expert-en-us © fos4X 2019