Capacities in accordance with DIN 18873-2
A600 technical data (FCS4043)
Specialty Hourly capacity
Cups/h (double dispensing)
Espresso 150 (194)
Café crème 100 (121)
Cappuccino 98 (160)
Hot water (200ml) 164
Bean hopper 2 kg with one grinder 2 x 1.2 kg with two grinders
Powder container 1.2 kg (may differ from this, depending on the powder used)
Grounds container 60-110 cakes, depending on the grind quantity (optional: coffee ground chute)
Boiler for coffee 0.9 l; operating pressure 800kPa (8bar); 230V; 2.5 kW (1.8 kW with 10 A fuse)
Boiler for hot water/steam 0.9 l; operating pressure 100kPa (2.1bar); 230V; 2.5 kW (1.8 kW with 10 A fuse)
Electrical connection
(see type plate)
EU 220 – 240 V/50 –60 Hz1L N PE2.4 kW – 2.8 kWFuse: 16 A (locked)
220 – 240 V/50 Hz1L N PE2.1 kW – 2.3  kWFuse: 10 A (locked)
USA 200 – 220 V/60  Hz2L PE4.5 kW – 5.3 kWFuse: 30  A (locked)
Japan 200  V/50 –60 Hz2L PE2.0 kWFuse: 16 A (locked)
China 220  V/50  Hz1L NPE2.4 kWFuse: 16 A (locked)
Noise emission < 70 dB
Weight Approx. 38kg
Fixed water connection G 3/8" outside thread
Water pipeline pressure 80 – 800 kPa (0.8 – 8.0 bar)
Water shut-off With check valve and filter
Water tank Internal/External (optional)
Wastewater tank Internal/External (optional)
Water hardness Max. 70 mg CaO/1 l water (7 dH, 13 °fH)
Ideal pH value 7
Funnel d = 50mm (2") with siphon
Drain pipe dmin = 1"
Ambient conditions Humidity: max. 80%
Ambient temperature: 10 - 32 ° C
Preparations
•The power connection for the coffee machine must be protected
by a ground fault circuit interrupter (FI).
•Each terminal of the power supply must be able to be interrupted
by a switch.
•The fixed water connection must have a water shut-off with a
check valve and filter that can be inspected and must meet the
requirements of the technical data.
•The fixed water connection to your coffee machine must be done
using the hose set that is supplied with it. Do not use any other
water hoses that happen to be present.
Installation
You must have completed these preparations before one of our Ser-
vice technicians can install the coffee machine for you.
Your Service technician will install your coffee machine and carry out
the initial commissioning. The technician will walk you through the
basic functions.
Your A600 must be properly installed so that you can operate it correctly – your service technician
will gladly do that for you. You'll have to take care of a few things first. You'll find the requirements
for problem-free enjoyment of your coffee machine here.