FMO 45 GN 81 / FMO 45 GN 86
– 10 –
EN
This clearance shouldn‘t beignored
as it‘s required for ventilation system
oftheappliance tooperate.
Right Place For Installation
Product has been designed tobemounted
toworktops procured from market. asafe
distance must beleft between theproduct and
kitchen walls orfurniture. See thedrawings
provided on pages 120-121 for proper
distances (values inmm).
Used surfaces, synthetic laminates and
adhesives must beheat resistant
(minimum 100°C)‘
Kitchen cupboards must belevel with
product and secured.
If there isadrawer below theoven, arack
must beplaced between oven and drawer.
WARNING: Do not install theproduct next
torefrigerators orcoolers. Theheat emitted by
theproduct increases theenergy consumption
ofcooling devices.
WARNING: Do not use door and/or handle
tocarry ormove theproduct.
45cm Built-In Oven Installation and
Mounting
Place ofuse for product must belocated
before starting installation. Product mustn‘t
beinstalled inplaces which are under
theeffect ofstrong air flow. Carry theproduct
with minimum two people. Do not drag
theproduct so that floor isn‘t damaged.
Remove all transportation materials inside and
outside theproduct. Remove all materials and
documents intheproduct.
Installation Under Counter
(figure 1 page 120)
Cabin must match thedimensions provided
infigure2 (page 120).
A clearance must beprovided at therear
part ofthecabin as indicated inthefigure so
that necessary ventilation can beachieved.
After mounting, theclearance between lower
and upper part ofthecounter isindicated
infigure5 (page 121) with „A“. It‘s for
ventilation and shouldn‘t becovered.
Installation inanElevated Cabinet
(figure 4 page 121)
Cabin must match thedimensions provided
infigure4 (page 121). Theclearances with
thedimensions indicated inthefigure must
beprovided at therear part ofcabin, upper and
lower sections so that necessary ventilation
can beachieved.
Installation Requirements
Product dimensions are provided
inthefigure3(page 120). Furniture surfaces
for mounting and mounting materials
tobeusedmust have aminimum temperature
resistance of100°C. Mounting cabin must
besecured and its floor must beplane for
product not totilt over. Cabin floor must have
aminimum strength that would handle
aload of60kg.
Placing and Securing theOven
Place theoven into thecabin with two
ormore people.
Ensure that oven‘s frame and front edge
ofthefurniture match uniformly.
Supply cord mustn‘t beunder theoven,
squeeze inbetween oven and furniture
orbend.
Fix theoven tothefurniture by using
thescrews provided with theproduct.
Screws must bemounted as shown
infigure5 (page 121) by passing them
through plastics attached toframe
oftheproduct.
Screws mustn‘t beovertightened.
Otherwise, screw sockets might
beworn. Check that oven doesn‘t
move after mounting. ifoven
isn‘t mounted inaccordance with
instructions, there isarisk oftilt over
during operation.
Electrical Connection
Mounting place oftheproduct must have
appropriate electrical installation.
Network voltage must becompatible with
thevalues provided on type label ofproduct.
Product connection must bemade
inaccordance with local and national
electrical requirements. Before starting
themounting disconnect network power. Do
not connect theproduct tonetwork until its
mounting iscompleted.