WLA300 Rev170606
28
This high voltage warning can be enabled or disabled by swiping the C 1 and C 2
sensors six times. (Factory default setting: disabled.)
When ENABLED Top 2 and Bottom 2 LEDs Blink
When DISABLED Top 6 LEDs Blink
To change the setting swipe the C 1 and C 2 sensors six times again. Then hold the
magnet at C 2 for ve seconds to set the calibration into memory.
To leave the setting as it is, let the processor time out and go back to normal display.
If the voltage from the
Pressure Sensor is more
than 4.6 volts, then it is
above normal range.
CODE 66
Top 2 and Bottom 2 LEDs
Blink ON and OFF
Apparatus at incline
(parked on a hill).
Not calibrated correctly.
Shorted wire / bad connector
on sensor cable.
Figure 9. Diagnostics - Warnings
The display cycles between normal and the following WARNINGS when a warning
condition exists.
Problem
Probable Cause
Display