EasyManua.ls Logo

FRC TankVisionPro WLA300 - System Specifications and Description; Component Specifications

FRC TankVisionPro WLA300
44 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
WLA300 Rev170606
6
Specications
Display Module
Supply Voltage: 9 - 30 VDC
Supply Current: 0.25 Amp Maximum
Dimensions: 4 3/8 by 3 Inches
Housing: Waterproof Polycarbonate with plastic lens and enclosure
to protect electronics
Indicators: Tri-Color of Bright LEDs (9/10 Rows)
Viewing Angle: 180°
Cab Miniature Display
Supply Voltage: 9 - 30 VDC
Supply Current: 0.5 Amp Maximum
Dimensions: 2 1/4 by 1 1/2 Inches
MaxVision LED Tank Display
Supply Voltage: 12/24 VDC
Supply Current: 1 Amp Maximum at 12 VDC
Dimensions: 14 3/8 by 1 7/8 Inches
Indicators: 96 Super Bright LEDs
Remote Light Driver
Supply Voltage: 9 - 30 VDC
Supply Current: 0.1 Amp Maximum
Switch: Solid State
Switching Voltage: 9 - 30 VDC
Switching Current: 20 AMPS Maximum @ 12 VDC
10 AMPS Maximum @ 24 VDC
Pressure Sensor
Housing: Stainless Steel with 1/4-18 NPT for Mounting
Sensor: Ceramic Diaphragm
Pressure Range: 0 - 5 PSI (Maximum Tank Height - 10 Feet)
Excitation Voltage: 5 VDC
Pressure/Vacuum Foam Tank Vent
Material: PVC and Aluminum with Delrin Valves
Relief Pressure: ±0.01 PSI
Maximum Flow Rate: Compensates 100% for Concentrate Flow Rates
Below 60 GPM

Table of Contents