Questions and Answers

  • A
    Annette WilliamsAug 19, 2025
    What to do if my FRIEDLAND SA1 siren sounds when disarmed or not triggered?
    • T
      Thomas SwansonAug 20, 2025
      If your FRIEDLAND Security System siren sounds when the system is disarmed or hasn't been triggered by an intruder, it could be due to several reasons: * A Detector tamper switch may be activated: Check that the battery covers of all detectors and Keypads are securely and fully fitted. * A Personal Attack Alarm may have been operated from a Remote Control or Keypad. * The Jamming detection circuit may be in operation. * A Detector may be giving false alarm signals.
  • B
    blevinsrebeccaAug 22, 2025
    Why is my FRIEDLAND Security System PIR movement detector giving false alarms?
    • Q
      qmccoyAug 22, 2025
      If your FRIEDLAND Security System PIR Movement Detector is false alarming, check the following: * Ensure that the detector is not pointing at a source of heat or a moving object. * Make sure that the detector is not mounted above a radiator or heater. * Verify that the detector is not facing a window or in direct sunlight. * Confirm that the detector is not in a draughty area. * The pulse count may be set too low: Reset to two pulse detection.
  • J
    James RogersAug 26, 2025
    What to do if FRIEDLAND SA1 siren is not responding to detector?
    • S
      Sarah GordonAug 26, 2025
      If the FRIEDLAND Security System siren is not responding to the detector, consider these potential causes: * Detector battery low: Replace the battery. * Siren in Service Mode: Switch back to Operating Mode using the Remote Control or Keypad. * Incorrect ‘House Code’: Ensure the ‘House Code’ is correctly set to the same code as all other system devices. * Detector out of range: Ensure the detector is within the effective radio range of the Siren, and verify that equipment is not mounted close to metal objects.
  • L
    lisa30Aug 28, 2025
    How to fix FRIEDLAND Security System PIR movement detector not detecting movement?
    • A
      Amy TerryAug 28, 2025
      If the FRIEDLAND Security System PIR Movement Detector is not detecting movement, consider the following: * Ensure the battery clip is securely connected. * Ensure ‘House Code’ is correctly set to the same code as all other system devices. * Pulse count set too high: Reset to one pulse detection. * Ensure DIP switches 1, 2 and 3 of SW2 are correctly set, (i.e. 1=ON, 2=ON, and 3=OFF). * Ensure that detector is mounted the correct way up, (i.e. with detection window at the bottom). * Ensure that the detector is mounted at the correct height, (i.e. 2-2.5m). * Allow up to three minutes for detector to stabilize and become fully operational. Leave the area for this period.
  • J
    Jennifer PowellAug 30, 2025
    Why does my FRIEDLAND Security System siren immediately sound when armed?
    • A
      Austin KingAug 30, 2025
      If the FRIEDLAND Security System siren sounds immediately when the system is armed, it is likely due to the siren tamper switch being activated. Adjust the tamper plunger and ensure that the switch fully closes when the siren is mounted. If the wall is excessively uneven, you may need to relocate the siren to a more suitable position.
  • K
    Kristopher MillerSep 2, 2025
    What causes false alarms in FRIEDLAND SA1 magnetic contact detectors?
    • C
      christinaherreraSep 2, 2025
      If the FRIEDLAND Security System Magnetic Contact Detector is false alarming, consider the following: * Ensure that the magnet is correctly positioned in relation to the detector. * Ensure that the gap between the magnet and the detector is less than 10mm. * Check that the tamper switch below the battery cover is depressed. Verify that the battery cover is fitted correctly and that the fixing lugs are not broken.
  • H
    hreedSep 5, 2025
    How to troubleshoot a FRIEDLAND Security System remote control with a dim or non-illuminating LED?
    • L
      Larry SmithSep 5, 2025
      If the LED on your FRIEDLAND Security System Remote Control is not illuminating or is dim when operated: * Ensure the battery is fitted with the correct polarity. * Ensure the battery holder connections are making good contact with the battery. * The battery may be low: replace it.
  • M
    Michael Foster Jr.Sep 8, 2025
    What should I do if my FRIEDLAND SA1 keypad is not operating?
    • C
      crystalsimpsonSep 8, 2025
      If your FRIEDLAND Security System keypad is not operating and the ‘On-Air’ light does not illuminate: * Ensure that the magnet is correctly positioned in relation to the detector and that the gap between the magnet and detector is not too large. * The battery may be low - replace the battery.
  • B
    Brittany Turner DVMSep 12, 2025
    What does it mean when the PIR movement detector LED flashes on my FRIEDLAND Security System?
    • J
      Justin BryantSep 12, 2025
      If the LED on your FRIEDLAND Security System PIR Movement Detector flashes when it detects movement (in normal operation mode), the battery is likely low, so replace the battery.
  • J
    Joseph HubbardSep 13, 2025
    Why does the LED on my FRIEDLAND Security System magnetic contact detector light up when I open a door or window?
    • R
      Richard CastroSep 13, 2025
      If the LED on your FRIEDLAND Security System Magnetic Contact Detector illuminates when a door or window is opened, it indicates a low battery. Replace the batteries.

Summary

Foreword and System Overview

Safety Precautions

Essential safety advice for tool usage, drilling, and ladder safety.

Introduction and System Features

Security Features

Covers tamper protection, jamming detection, and house code security.

External Solar Siren Installation

Siren Positioning Guidelines

Recommendations for optimal siren placement for visibility and reception.

Siren Installation and Configuration

Step-by-step instructions for mounting and setting up the solar siren.

Remote Control Unit Setup

Remote Control Configuration

Steps to set the house code and prepare the remote control.

Keypad Setup and Code Management

Keypad Installation and Mounting

Guidance on where and how to mount the keypad.

Changing User Access Code

Instructions for setting a new personal access code for the keypad.

PIR Movement Detectors

PIR Detector Placement and Installation

PIR Detector Positioning Guidelines

Recommends optimal placement for PIR detectors to avoid false alarms.

PIR Detector Installation Steps

Step-by-step guide for mounting and configuring PIR detectors.

Magnetic Contact Detectors

Magnetic Contact Detector Placement

Advice on where to install magnetic contact sensors for doors/windows.

Magnetic Contact Detector Installation

Instructions for fitting and configuring magnetic contact detectors.

Magnetic Contact Detector Testing

System Testing and Operation

Testing the Complete System

Comprehensive tests for all system components after installation.

System Arming, Disarming, and PA Alarm

Siren Modes and Battery Status

Maintenance and Batteries

Troubleshooting Siren Issues

Troubleshooting Detectors and Keypad

Component Specifications

FRIEDLAND SA1 Specifications

General IconGeneral
BrandFRIEDLAND
ModelSA1
CategorySecurity System
LanguageEnglish

Related product manuals