TESTING THE SYSTEM
INITIAL TESTING
As the system is initially installed it is recommended
that each device is tested in turn as it is installed, (refer
to testing instructions for particular device).
TESTING AN INSTALLED SYSTEM
1. Before commencing testing please ensure the
following conditions apply:
- The system is in Operating Mode and Disarmed
- There is no movement in any PIR protected area.
-
All doors/windows protected by Magnetic Contact
Detectors are closed.
- All battery covers and housings are correctly
fitted.
2. Arm the system in Instant-Arm mode by pressing
the button on the Remote Control.
The Siren will acknowledge the signal by beeping
once, (unless Beep Disable has been selected).
3. After 2 minutes walk into an area protected by a
PIR Movement Detector and ensure that a Full
Alarm condition is initiated, (i.e. the Siren sounds).
Note: To conserve power and maximise battery
life the PIR Detector will only detect movement if
there has been no movement detected within the
previous 2 minutes.
4. Disarm the system by pressing the button
on the Remote Control.
The Siren will acknowledge the signal by beeping
once, (unless Beep Disable has been selected)
and the Siren will stop
5. Continue to test all PIR Movement Detectors in
turn as described above, (steps 2 - 4). Remember
that the detectors need to settle for at least 40
seconds between each activation.
6. Arm the system in Instant-Arm mode by pressing
the button on the Remote Control.
7. Open a door/window protected by a Magnetic
Contact Detector and ensure that a Full Alarm
condition is initiated.
8. Disarm the system and stop the Siren by pressing
the button on the Remote Control.
9. Test each Magnetic Contact Detector in turn as
described above, (steps 6 - 8).
10. Arm the system at the Keypad by entering the
User Access Code followed by the ‘INSTANT-
ARM’ button.
,
11. Press and hold both ‘DELAY-ARM’ buttons on the
Keypad for approx 2-3 seconds.
and
A Full Alarm condition will be initiated.
12. Stop the Siren and Disarm the system by entering
the User Access Code followed by the DISARM
button on the Keypad.
,
Note: It is recommended that the system is tested at
regular intervals, (every 3 months), to ensure that all
elements of the system are operating correctly.
OPERATING
INSTRUCTIONS
When leaving the premises, the system must be
Armed. However, before doing so, check that all
windows are closed and locked, all protected doors
are closed and PIR Movement Detectors are not
obstructed. Ensure that pets are restricted to areas
not protected by PIR Movement Detectors.
The system has two armed modes, Instant-Arm and
Delay Arm.
Instant-Arm mode will immediately set the system into
a fully armed state. Once the system is armed,
activating any detector, (i.e. opening a door/windows
protected by a Magnetic Contact Detector or moving
into a PIR protected area), will immediately generate a
Full Alarm condition. On returning to and entering the
property the system must be Disarmed before
opening any protected door or entering an area
protected by a PIR Movement Detector otherwise a
Full Alarm condition will occur. For this reason it is
usual only to set the system into Instant-Arm mode
and to Disarm the system from outside the property.
Delay-Arm mode will arm the system with a 15 second
entry/exit delay. On arming the system in Delay mode
SA1, SA2(PF), SAC1 15
User Access Code
User Access Code