EasyManua.ls Logo

FRIEDLAND SA1 - System Arming, Disarming, and PA Alarm; Arming Modes; Disarming the System; Personal Attack Alarm

FRIEDLAND SA1
24 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
the siren will produce a single long beep and another
short beep after the 15s exit-delay has expired. This
allows time for you to leave the property before the
system becomes fully active. On returning to and
entering the property by opening a protected door or
moving through a PIR protected area the system will
be triggered and the Siren will emit a single long beep.
However, a Full Alarm will not be initiated until the 15
second entry-delay has expired during which time the
system should be Disarmed. If the system is not
Disarmed when the entry-delay period expires an
alarm condition will occur and the siren will activate.
If an Alarm condition is initiated the Siren will sound
continuously until the set alarm duration time expires
when the Siren will cease. The system will then
automatically reset and re-arm itself. In the event of a
further alarm condition being initiated the system will
once again activate the Siren for the set alarm
duration. This process can be repeated up to three
times after which time the Zone Lockout feature will
operate and prevent the system from re-arming.
Notes: - To conserve power and maximise battery
life the PIR Detector will only detect
movement if there has been no movement
detected within the previous 2 minutes.
- The system can only be armed if the Siren is
in Operating Mode, (see page 17).
ARMING THE SYSTEM IN
INSTANT-ARM MODE
The system can be armed in Instant mode using either
the Remote Control or the Keypad as follows:
Remote Control:
Press the INSTANT-ARM button,
The Siren will acknowledge the signal by beeping
once.
Keypad:
Enter the User Access code followed by the
INSTANT-ARM button
,
The Siren will acknowledge the signal by beeping
once.
ARMING THE SYSTEM IN
DELAY-ARM MODE
The system can be armed in Delay mode using either
the Remote Control or the Keypad as follows:
Remote Control:
Press the DELAY-ARM button,
The Siren will acknowledge the signal by beeping
once and then again after the 15s entry/exit
period has expired. The system will not be fully
armed and active until after the second beep.
Keypad:
Enter the User Access code followed by either
DELAY-ARM button.
, or
The Siren will acknowledge the signal by beeping
once and then again after the 15s entry/exit
period has expired. The system will not be fully
armed and active until after the second beep.
DISARMING THE SYSTEM
The system can be Disarmed using either the Remote
Control or the Keypad as follows:
Remote Control:
Press the DISARM button,
The Siren will acknowledge the signal by beeping
twice.
Keypad:
Enter the User Access code followed by the
DISARM button.
,
The Siren will acknowledge the signal by beeping
twice.
IMPORTANT: If, when the system is disarmed, the
siren emits a series of ten rapid beeps, this indicates
that a Full Alarm condition has been triggered whilst
the system was armed. Check the security of the
property before entering.
PERSONAL ATTACK (PA) ALARM
A full alarm condition can be immediately initiated by
the user at any time (whether the system is armed or
disarmed) in the event of threat or danger by activating
the Personal Attack (PA) facility using eitherthe Remote
Control or the Keypad as follows:
2
16 SA1, SA2(PF), SAC1
User Access Code
User Access Code
User Access Code

Related product manuals