FAULT RECTIFICATION
© frifri Aro SA 7-1 OM - 1.0 - 25.10.2004
7. Fault rectification
7.1 Check list for fault finding
Display Problem Effect Cause Measure
Thermoelement The deep fryer will
not start.
The thermal
element con-
nection cables
are not connected
or have come
loose.
Connect the
thermoelement
correctly.
Overheating The deep fryer
stops the heating
and frying
process.
The frying oil level
is too low.
The thermostat
is defect.
Top up with
sufficient
frying oil.
Replace
thermostat.
Thermoelement The deep fryer
stops the
heating and
frying process.
The thermal
element con-
nection cables
have been con-
nected the wrong
way round.
Connect the
thermoelement
correctly.
Can only be
localized by a
service
technician.
The deep fryer
is blocked from
frying opera-
tion.
A software
or hardware
defect is
present.
Intervention by
a service techni-
cian is
necessary.