Operating the system
Filling/ refilling the store with fuel
Page 24
B 067 03 11_en v
3
3.2.5 Blowing in pellets for an empty store with stirrer
CAUTION! If the head of the stirrer is already free of material
and the arms / spring blades are extended, then the feeder
unit must be active during the filling process, however the
boiler must be in “OFF” status.
Switch off the boiler using the standby key ( ) and switch off main
switch
Switch off main switch of expension switch cabinet (if available)
Put residual fuel (corners, walls) in the storage room onto the top of
the outfeeder-system
Take care to the instructions for working in the fuel storage room
See notes in the access area of the storage room
After working in the storage room:
Switch on main switch of the boiler and the expension switch cabinet
(if available)
Press and hold the party key ( )for 5 seconds
“Extra heating” mode is activated
Wait until the arms / spring blades are touching the head of the
stirrer (about 2 turns)
Switch off the boiler using the standby key ( ) and allow it to cool
down for at least two hours.
Close all openings to the store to seal out dust
Blow the fuel into the store
If the storage room is completely empty and there is no residual fuel:
Contact Froling before filling the store