EasyManua.ls Logo

Fronius 10.0-3 208-240 - USB Stick as a Data Logger and for Updating Inverter Software; USB Flash Drive as a Data Logger; Data on the USB Thumb Drive

Fronius 10.0-3 208-240
68 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
USB Stick as a Data Logger and for Updating
Inverter Software
USB Flash Drive
as a Data Logger
A USB flash drive connected to the USB A socket can act as a data logger for an
inverter.
The logging data that is saved on the USB flash drive can be viewed directly in third-
party applications (e.g., Microsoft® Excel) at any time via the included CSV file.
Older Excel versions (up to Excel 2007) have a row limit of 65536.
Data on the USB
thumb drive
If the USB thumb drive is used as a datalogger, three files are automatically created:
- FRONIUS.sys system file:
This file saves information from the inverter that is irrelevant to the customer. The file
must not be deleted separately. Only delete all files together (sys, fld, csv).
- DALO.fld log file:
Log file for reading out data in Fronius Solar.access.
You can find additional information on the Fronius Solar.access software in the
“DATCOM Detail” Operating Instructions at http://www.fronius.com
- DATA.csv log file:
A log file for reading out data in a spreadsheet program (e.g., Microsoft® Excel)
USB_Drive (1)
(2)
01 (3)
02
FRONIUS.sys
DALO.fld
DATA.csv
FRONIUS.sys
DALO.fld
DATA.csv
GALVO / SYMO / PRIMO / ECO
Data structure on the USB thumb drive
(1) USB root directory
(2) Fronius inverter (Fronius Galvo,
Fronius Symo Advanced, Fronius
Primo, or Fronius Eco)
(3) Inverter number – can be set in the
setup menu under DATCOM
If multiple inverters exist with the same
inverter number, the three files are saved
in the same folder. A number is appended
to the file name (e.g., DALO_02.fld)
Structure of the CSV file:
(1) (2) (3)
(4)
(5) (6) (7)
57