Function of SynchroPulse in "Special 4-step" mode
I-S = Starting current
phase
SL = Slope
I-E = End-crater phase v = Wire feed speed
Iv
D
Al.2
LSLS
+ +
dFd
1/F
v
I-S
dFd
t
I-E
SynchroPulse function