dSP | Axx
Fault in the central control and regulation unit
Contact After-Sales Service
Cause:
Remedy:
dSP | Cxx
Fault in the central control and regulation unit
Contact After-Sales Service
Cause:
Remedy:
dSP | Exx
Fault in the central control and regulation unit
Contact After-Sales Service
Cause:
Remedy:
dSP | Sy
Fault in the central control and regulation unit
Contact After-Sales Service
Cause:
Remedy:
dSP | nSy
Fault in the central control and regulation unit
Contact After-Sales Service
Cause:
Remedy:
E-S | toP
only with the External stop and External stop - inching enabled options
The External stop or External stop - inching enabled option has tripped
Acknowledge the service code via the robot control unit and re-apply the 24
V SELV safety voltage
Cause:
Remedy:
EFd | xx.x
Fault in the wire feed system (overcurrent in wire-feed unit drive)
Arrange the hosepack in as straight a line as possible; check that there are
no kinks or dirt in the inner liner; check the contact pressure on the 2-roller
(or 4-roller) drive
Wire-feed unit motor is sticking or defective
Check or replace the wire-feed unit motor
Cause:
Remedy:
Cause:
Remedy:
EFd | 8.1
Fault in the wire feed system (overcurrent in wire-feed unit drive)
Arrange the hosepack in as straight a line as possible; check that there are
no kinks or dirt in the inner liner; check the contact pressure on the 2-roller
(or 4-roller) drive
Wire-feed unit motor is sticking or defective
Check or replace the wire-feed unit motor
Cause:
Remedy:
Cause:
Remedy:
EFd | 8.2
Fault in the wire feed system (overcurrent in wire-feed unit drive)
Arrange the hosepack in as straight a line as possible; check that there are
no kinks or dirt in the inner liner; check the contact pressure on the 2-roller
(or 4-roller) drive
Cause:
Remedy:
176