Err | 050
Intermediate circuit-balance error
Contact After-Sales Service
Cause:
Remedy:
Err | 051
Mains undervoltage: The mains voltage has fallen below the tolerance
range
Check the mains voltage
Cause:
Remedy:
Err | 052
Mains overvoltage: The mains voltage has risen above the tolerance range
Check the mains voltage
Cause:
Remedy:
Err | 054
“Sticking” of the wire in the solidifying weld pool
Cut off the sticking wire end;
there is no need to acknowledge this error message
Cause:
Remedy:
Err | 056
The "Wire-end check" option has detected the end of the wire electrode
Insert a new wirespool and feed the wire electrode into the hosepack;
acknowledge Err | 056 by pressing the Store button
Additional fan filter of the VR 1500 - 11 / 12 / 30 is contaminated
air supply for the additional fan is no longer sufficient to cool the power elec-
tronics
the power electronics temperature switch has tripped
Clean filter or replace;
acknowledge Err | 056 by pressing the Store button
Excessive ambient temperature on the VR 1500 - 11 / 12 / 30
Reduce ambient temperature
if necessary position and operate welding machine at a cooler location;
acknowledge Err | 056 by pressing the Store button
Excessive motor current on the VR 1500 - 11 / 12 / 30, e.g. due to wire feed
problems or an adequately dimensioned wire-feed unit
Check wire feed conditions, rectify errors;
acknowledge Err | 056 by pressing the Store button
VR 1530 wire-feed unit cover open or interlock release handles not snapped
into place
Close VR 1530 wire-feed unit cover properly
acknowledge Err | 056 by pressing the Store button
Cause:
Remedy:
Cause:
Remedy:
Cause:
Remedy:
Cause:
Remedy:
Cause:
Remedy:
Err | 062
"E62“ is displayed on the TP 08 remote control at the same time
Overheating of TP 08 remote control
Allow TP 08 remote control to cool down
Cause:
Remedy:
Err | 069
Illegal mode change during welding (e.g. changing from a MIG/MAG job to a
TIG job)
Re-start welding action
Cause:
Remedy:
179
EN
Toowoomba Welding Supplies : tweld.com.au : Ph +61 7 4659 0044

Table of Contents

Other manuals for Fronius CMT 4000 Advanced

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fronius CMT 4000 Advanced and is the answer not in the manual?

Fronius CMT 4000 Advanced Specifications

General IconGeneral
BrandFronius
ModelCMT 4000 Advanced
CategoryAC Power Distribution
LanguageEnglish

Related product manuals