EasyManua.ls Logo

Fronius CWF 25i - Water-Cooled Interconnecting Hosepack - HP 70 I CWF con;W; Disposal

Fronius CWF 25i
48 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Water-cooled in-
terconnecting
hosepack - HP
70i CWF
CON /W
DC welding current at
10 min / 40°C (104°F)
40% ED
1)
/ 400 A
60% ED
1)
/ 365 A
100% ED
1)
/ 320 A
AC welding current at
10 min / 40°C (104°F)
40% ED
1)
/ 400 A
60% ED
1)
/ 365 A
100% ED
1)
/ 320 A
Shielding gas
(Standard EN 439)
Argon
Length 2.0 / 5.0 / 10.0 m
6 feet 6.74 inch / 16 feet 4.85 inch /
32 feet 9.70 inch
Minimum coolant flow Q
min
1 l/min
0.26 gal. (US) / min
Minimum coolant pressure p
min
3 bar
43 psi
Maximum coolant pressure p
max
5.5 bar
79 psi
Maximum permitted open circuit
voltage (U
0
)
113 V
Maximum permitted striking voltage
(U
P
)
10 kV
1)
ED = Duty cycle
Disposal Materials should be disposed of according to valid local and national regulations.
46