Fronius Primo GEN24 4.6 / 4.6 Plus 5.0 / 5.0 Plus 6.0 / 6.0 Plus
Number of inputs - PV1 2
Number of inputs - PV2 2
DC input data battery
Max. voltage 455 V
Min. voltage 150 V
Max. current 22 A
Max. output
4600 W 5000 W 6000 W
DC inputs
1
DC overvoltage category
(in accordance with IEC 62109-1)
2
AC input/output data
Nominal output power (P
nom
) 4600 W 5000 W 6000 W
Max. output power 4600 W 5000 W 6000 W
Nominal grid voltage 1 ~ NPE 220V / 230V / 240 V
Min. grid voltage
155 V
1)
Max. grid voltage
270 V
1)
Max. output current 27.5 A
Starting current
6)
20 A / 1.3 ms
Nominal frequency
50 / 60 Hz
1)
Nominal frequency for Full Backup
53 / 63 Hz
1)
Total harmonic distortion < 3.5%
Power factor cos phi
2)
0.8-1 (adjustable)
Max. permitted mains impedance Z
max
on PCC
4)
None
Max. output residual current per duration 29 A / 3 ms
AC output data PV Point
Max. output power 4133 W (for 5 s)
Nominal output power 3000 W
Nominal output current 13 A
Nominal grid voltage
1 ~ NPE 220 V / 230 V / 240 V
Nominal frequency
53 / 63 Hz
1)
Switchover time < 90 s
Power factor cos phi
2)
0 - 1
AC output data Full Backup
Max. output power 12400 W (for 5 s)
Max. output power (per phase)
4133 W (for 5 s)
Nominal output power
4600 W 5000 W 6000 W
140