Load manage-
ment
Priorities
If additional components (e.g. battery, Ohmpilot) are present in the system, the
priorities can be set here. Devices having higher priority are actuated first, and
subsequently, if there is still excess energy available, the other devices.
Load management
It is possible for up to four different load management rules to be defined. At
the same threshold values, the rules are activated in succession. For deactiva-
tion, this is done in reverse; the I/O last switched on is the first to be switched
off. In the case of different thresholds, the I/O with the lowest threshold is
switched on first, followed by the second lowest, and so on.
I/Os controlled by the produced power are always prioritised over a battery and
Ohmpilot. That is to say that an I/O can switch on and result in the battery no
longer being charged or the Ohmpilot no longer being activated.
An I/O is activated or deactivated only after 60 seconds.
Control
-
Control is deactivated.
-
Control is effected by the power generated.
-
Control is effected by excess power (given feed limits). This option can only
be selected if a meter has been connected. Control via Energy Manager is ef-
fected using the actual power of feeding in with respect to the grid.
Thresholds
-
On: For entering an effective power limit, at which the output is activated.
-
Off: For entering an effective power limit, at which the output is deactivated.
Runtimes
-
Field for enabling a minimum duration for which the output is to be activated
for each switch-on process.
-
Field for enabling the maximum runtime per day.
-
Field for enabling a target duration for which the output is to be activated in
total per day (total of several switch-on processes).
111
EN

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fronius Primo GEN24 3.0 and is the answer not in the manual?

Fronius Primo GEN24 3.0 Specifications

General IconGeneral
Max. apparent AC power3.0 kVA
Max. output current (at AC nom. voltage)13.0 A
AC voltage range180 - 280 V
Frequency50 / 60 Hz
THD< 3 %
Max. input current (DC)12.5 A
Max. input current per MPP tracker12.5 A
Protection classIP66
AC Nominal Power3.0 kW
Operating Temperature Range-25 - 60 °C