Input currents of digital inputs depending on the input voltage;
input resistance = 70 kOhm
Total power for digital output
(internal supply)
6 W at 12 V (USB not connected)
Power per digital output
(external supply)
1 A at >12.5 V-24 V
(max. 3 A in total)
Datalogger/web server Integrated
Fronius Primo
GEN24 4.6 / 4.6
Plus
DC input data
MPP voltage range
(at rated power)
230 - 530 V
Max. input voltage
at 1000 W/m²/-10 °C in an open cir-
cuit
600 V
Min. input voltage 65 V
Feed-in start-up input voltage in grid
operation
5)
80 V
Max. input current
PV 1
PV 2
22.0 A
12.0 A
Max. short circuit current of solar
modules (I
SC PV
)
PV 1
PV 2
33 A
18 A
Max. short circuit current
(I
SC PV1
+ I
SC PV2
= I
SC max
)
Total
51 A
Max. inverter backfeed current to the
array
3)
33 / 18 A
Number of inputs - PV 1 2
Number of inputs - PV 2 2
Max. capacity of the PV generator
against earth
920 nF
DC input data battery
Max. voltage 455 V
Min. voltage 150 V
Max. current 22 A
Max. output 4600 W
DC inputs 1
AC input/output data
Nominal output power (P
nom
) 4600 W
Max. output power 4600 W
Rated apparent power 4600 W
162