Technical data
Fronius Primo
GEN24 3.0 / 3.0
Plus
DC input data
MPP voltage range
(at rated power)
190 - 530 V
Max. input voltage
at 1000 W/m²/-10 °C in an open cir-
cuit
600 V
Min. input voltage 65 V
Feed-in start-up input voltage in grid
operation
5)
80 V
Max. input current
PV 1
PV 2
22.0 A
12.0 A
Max. short circuit current of solar
modules (I
SC PV
)
PV 1
PV 2
33 A
18 A
Max. short circuit current
(I
SC PV1
+ I
SC PV2
= I
SC max
)
Total
51 A
Max. inverter backfeed current to the
array
3)
33 / 18 A
Number of inputs - PV 1 2
Number of inputs - PV 2 2
Max. capacity of the PV generator
against earth
600 nF
DC input data battery
Max. voltage 455 V
Min. voltage 150 V
Max. current 22 A
Max. output 3000 W
DC inputs
1
AC input/output data
Nominal output power (P
nom
) 3000 W
Max. output power 3000 W
Rated apparent power 3000 W
Nominal grid voltage 1 ~ NPE 220V / 230V / 240 V
Min. grid voltage
155 V
1)
Max. grid voltage
270 V
1)
Max. output current
19.4 A
Current (inrush)
6)
20 A / 1.3 ms
154