Loading...
Combined solar module strings with total cur-
rent
(I
dcmax
) greater than or equal to 22 A
MPPT settings:
PV 1: ON
PV 2: OFF
PV 1 + PV 2 (connected in parallel):
ON
IMPORTANT!
Splitting the total current (I
dcmax
) by
bridging from PV 1 to PV 2 at the ter-
minal is permitted up to ≤ 34 A.
Connecting the
solar module
strings to the in-
verter
1
+ -
1
2
2
Push the DC cables through the DC
bushings by hand.
IMPORTANT!
Before stripping the insulation, push
the cables through the DC bushings to
prevent individual wires being bent or
broken.
70