Set the Process Data Width of the Bus Module
Setting the pro-
cess data width
of the bus modu-
le
Note down the IP address of the power source used:
1
On the power source control panel, select "Defaults"
2
On the power source control panel, select "System"
3
On the power source control panel, select "Information"
4
Note down the displayed IP address (example: 10.5.72.13)
Open website of the power source in the internet browser:
5
Connect the computer to the network of the power source
6
Enter the IP address of the power source in the search bar of the internet
browser and confirm
7
Enter the standard user name (admin) and password (admin)
-
The website of the power source is displayed
Set the process data width of the bus module:
8
On the power source website, select the "RI FB PRO/i" tab
9
Under "Process data", select the desired process data configuration
10
Select "Save"
-
The field bus connection is restarted and the configuration is applied