EasyManua.ls Logo

Fronius RI FB PRO/i - Page 35

Fronius RI FB PRO/i
44 pages
Go to English
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Address
Signal
Activity/
Data type
Range
Factor
Process
image
Relative
Absolu-
te
Standard
Economy
WORD
BYTE
BIT
BIT
6
12,
13
0–7 96–111
For the welding processes
MIG/MAG pulse synergic,
MIG/MAG standard syner-
gic,
MIG/MAG PMC,
MIG/MAG LSC,
CMT:
Arclength correction
SINT16
-10.0 to
10.0
[steps]
10
ü ü
For the welding process
MIG/MAG standard manu-
al:
Welding voltage
UINT16
0.0 to
6553.5
[V]
10
For job mode:
Arclength correction
SINT16
-10.0 to
10.0
[steps]
10
For the welding process
ConstantWire:
Hotwire current
UINT16
0.0 to
6553.5
[A]
10
7
14,
15
0–7 112–127
For the welding processes
MIG/MAG pulse synergic,
MIG/MAG standard syner-
gic,
MIG/MAG PMC,
MIG/MAG LSC,
CMT:
Pulse-/dynamic correction
SINT16
-10.0 to
10.0
[steps]
10
ü ü
For the welding process
MIG/MAG standard manu-
al:
Dynamic
UINT16
0.0 to 10.0
[steps]
10
8
16 0–7 128–135
Wire retract correction UINT16
0.0 to 10.0
[steps]
10
ü
17 0–7
136–
143
9
18 0–7
144–
151
Welding speed UINT16
0.0 to
1000.0
[cm/min]
10
ü
19 0–7
152–
159
10
20 0–7
160–
167
Arc length stabilizer SINT16 0.0 to 5.0 10
ü
21 0–7
168–
175
35