EasyManua.ls Logo

Fronius RI FB PRO/i - Page 35

Fronius RI FB PRO/i
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Address
Signal
Activity/
Data type
Range
Factor
Process
image
Relative
Absolu-
te
Standard
Economy
WORD
BYTE
BIT
BIT
6
12,
13
0–7 96–111
For the welding processes
MIG/MAG pulse synergic,
MIG/MAG standard syner-
gic,
MIG/MAG PMC,
MIG/MAG LSC,
CMT:
Arclength correction
SINT16
-10.0 to
10.0
[steps]
10
ü ü
For the welding process
MIG/MAG standard manu-
al:
Welding voltage
UINT16
0.0 to
6553.5
[V]
10
For job mode:
Arclength correction
SINT16
-10.0 to
10.0
[steps]
10
For the welding process
ConstantWire:
Hotwire current
UINT16
0.0 to
6553.5
[A]
10
7
14,
15
0–7 112–127
For the welding processes
MIG/MAG pulse synergic,
MIG/MAG standard syner-
gic,
MIG/MAG PMC,
MIG/MAG LSC,
CMT:
Pulse-/dynamic correction
SINT16
-10.0 to
10.0
[steps]
10
ü ü
For the welding process
MIG/MAG standard manu-
al:
Dynamic
UINT16
0.0 to 10.0
[steps]
10
8
16 0–7 128–135
Wire retract correction UINT16
0.0 to 10.0
[steps]
10
ü
17 0–7
136–
143
9
18 0–7
144–
151
Welding speed UINT16
0.0 to
1000.0
[cm/min]
10
ü
19 0–7
152–
159
10
20 0–7
160–
167
Arc length stabilizer SINT16 0.0 to 5.0 10
ü
21 0–7
168–
175
35
EN-US

Table of Contents