Contact current The following points must be observed during the contact current measurement:
- Do not perform the measurement until the ground conductor current measurement
has been carried out successfully
- The device must be in charge mode
The measurement is taken between a grounded point and the conductive part that can
be touched and that is not connected to the ground conductor.
The contact current must not exceed 0.5 mA.
PE
mA
L1
1
2
9
N
PE L1 N
9
8
6.2
R
i
1-2kΩ
1 Measuring device
2 Battery charging system
6.2 Touchable, conductive part not connected to
the ground conductor
8 Isolated setup of test piece
9 Measuring line
Ri 1 - 2 kW
(6.2)(6.2)
Example: 6.2 Conductive part that can be touched
not connected to the ground conductor