Fan test
To start the fan test, set the "Fan" menu
item to "ON".
- The fan power (Ifan) and fan supply
voltage (Uprim) are displayed for
checking.
- The test duration is 20 seconds.
A tick appears next to the menu item once
the test has been completed.
Measuring the charging current
Preparations:
- Short circuit the charging lead
- Prepare the charging current meas-
urement.
To start measuring the charging current,
set the "Current Test" menu item to "ON".
- The charging current (Current) and
voltage (Voltage) are displayed for
checking.
A tick appears next to the menu item once
the test has been completed.