Clipping the Inverter onto the Mounting Bracket
Clipping the In-
verter onto the
Mounting Brack-
et
WARNING!
Danger due to inadequate ground conductor connection.
This can result in severe personal injury and damage to property.
▶
The housing screws provide an adequate ground conductor connection for
grounding the housing and should not be replaced under any circumstances
by other screws that do not provide a reliable ground conductor connection.
Due to the high weight, two people are required to clip the inverter into the
mounting bracket.
NOTE!
The inverter is fitted with a lock for safety reasons, which allows the inverter to
be pivoted in the mounting bracket only when the DC main switch is off.
▶
Only clip on and pivot the inverter in the mounting bracket when the DC
main switch is off.
▶
Do not use excessive force to clip on the inverter and pivot it.
The fixing screws in the data communication area of the inverter are used to fix
the inverter to the mounting bracket. Fixing screws must be properly tightened
to ensure correct contact between the inverter and the mounting bracket.
CAUTION!
Danger due to improperly tightened fixing screws.
When the inverter is in operation, this can result the formation of arcs, which in
turn may lead to fires.
▶
Always tighten the fixing screws with the specified torque.
Use a torque screwdriver to insert the
screws into the inverter. Do not use a
conventional cordless screwdriver –
the tightening torque will not be suffi-
ciently accurate.
Before attaching the Datcom cover, check the seals on the back for damage. If
there is damage, replacement covers (DatCom Cover Upgrade Kit) must be
ordered.
56