Para-
meter Description Range Unit
Anti-stick
When the anti-stick function is active, the arc
is extinguished after 1.5 seconds in the event
of a short circuit (sticking of the electrode)
Factory setting: ON (activated)
On
OFF
Start ramp
To activate/deactivate grinding mode
Factory setting: ON (activated)
On
OFF
Break voltage (Voltage cut off)
Used to specify at which arc length the weld-
ing process is to be completed.
The welding voltage increases as the length of
the arc increases. The arc is extinguished
when it reaches the voltage specified here
Factory setting: 45 volts
25 - 90 Volts
Factory setting (FACtory)
This can be used to reset the device to its
factory settings
-
cancel reset no
-
reset the parameters for the selected
welding process to their factory settings
YES
-
reset the parameters for all welding pro-
cesses to their factory settings
ALL
Resetting of the selected value to its
factory setting must be confirmed by
pressing the adjusting dial.
Level 2 Setup menu
To set general welding parameters
For details, see the "Level 2 Setup menu" sec-
tion