Connecting the mains cable
General If no mains cable is connected, a mains cable that conforms to the requisite connection
voltage must be fitted before commissioning.
A strain-relief device for the following cable cross-sections is installed on the power source:
*) Canada/US cable type: Extra-hard usage
Strain-relief devices for other cable cross-sections must be designed accordingly.
Stipulated mains
cables and strain-
relief devices
*) Canada/US cable type: Extra-hard usage
The item numbers of the different cables can be found in the spare parts list towards the
end of the document.
American wire gauge
Connecting the
mains cable
If no mains cable is connected, a mains cable that is suitable for the connection voltage
must be fitted before commissioning.
CAUTION!
If no ferrules are used, there is a risk of injury and damage from short circuits be-
tween the phase conductors or between the phase conductors and the PE conduc-
tor.
Fit ferrules to all phase conductors and the PE conductor of the stripped mains cable.
The PE conductor should be approx. 10 - 15 mm (0.4 - 0.6 in.) longer than the phase con-
ductors.
Power source Cable cross-section
Canada/US Europe
TSt 3500 AWG 12 *) 4G2.5
TSt 5000 AWG 10 *) 4G4
TSt 3500 MV AWG 10 *) 4G4
TSt 5000 MV AWG 6 *) 4G10
Power source Mains voltage Cable cross-sec-
tion
Canada/US
Europe
TSt 3500 3 x 380 / 400 V AWG 12 *) 4G2.5
3 x 460 V AWG 12 *) 4G2.5
TSt 5000 3 x 380 / 400 V AWG 8 *) 4G4
3 x 460 V AWG 10 *) 4G4
TSt 3500 MV 3 x 208 / 230 / 400 /
460 V
AWG 10 *) 4G4
TSt 5000 MV 3 x 208 / 230 / 400 /
460 V
AWG 6 *) 4G10